Water-cooled constant temperature electric vaporization controller description
The controller adds water cooling thermostat function based on all the control functions and structural advantages of the GN-787E series electric vaporization controller.
Combined with water-cooled electric vaporization burner, it can realize constant temperature vaporization, improve work stability and reliability, and is an upgraded product of electric vaporization.
The controller is a plastic shell moisture-proof structure, with its own lead-out line, which is used for electric heating and alcohol-free gasification stove without fan. In addition to the functions of conventional heating, temperature measurement, temperature control, ignition output, electromagnetic pump gear output, etc. There is a model with its own precision fire regulation to choose, it can realize the stepless precision adjustment and start and stop control of the oil pump flow. This function and the gear position adjustment realize the effect of no need to switch, fire with heart, and start and stop freely.
The system can be connected with a rocker switch, which can be customized with wireless remote control function or infrared anti-air burning function to achieve more intimate operation, control and energy saving effect. Basic parameters 1, rated working voltage: AC220V 2, normal working voltage range: AC187-242V
3, the service life: the number of actions is not less than 100,000 times 4, heating output power: no more than 2000W
5, ignition output: AC220V, power is not more than 50W
6, electromagnetic pump output: AC220V, power is not more than 100W, full power range PWM voltage regulation
7, water-cooled solenoid valve output: AC220V, power is not more than 50W 7, temperature probe: K-type thermocouple
8, remote control distance: not less than 15 meters no blocking situation
9, personality function: wireless remote control function optional Precision firepower adjustment function optional Wiring instructions
Important note: For safety reasons, the electric vaporization stove power supply must be installed with a 2P circuit breaker with leakage protection of not less than 20A! The metal casing of the stove must be reliably grounded! Wiring is shown in the figure: Setting instructions
1. Restore the factory settings: first press and hold the “minus” button and then turn on the power. When you see “rEc”, release the “minus” button and press and hold the setting button until you see “SAU”, indicating that the factory reset is successful. The settable parameters are returned to the factory state.
2. Modify the output parameter of the electromagnetic pump: press and hold the setting button for about 5 seconds, display d-1, indicating to enter the first file output parameter setting menu, and then press the setting button, the digital tube displays the current output percentage of the gear, at this time press Increase or decrease the button, the output parameters can be adjusted between 0-100.
★ After adjusting the parameters, press and hold the setting button until you see SAU, indicating that the parameters are saved successfully.
★ After adjusting the first gear parameters, if you need to adjust other gear parameters, you can press the setup button again to return to display d-1, and the data is temporarily stored. Press the minus button to enter d-2, d-3 and other gears in turn, and set the parameters according to the above method. Finally, press and hold the setting button until SAU is displayed, and all parameters before saving are completed at one time.
★ Can't see SAU will not save new parameters! The system still runs as originally.
3, modify the function parameters: display d-5 and then press the minus button, the function menu of the English abbreviation will be displayed.
1 SP menu is the target temperature value option; default value: 190 ° C; setting range: 130-300 ° C.
Meaning: Heating to this temperature stops preheating.
★ Press the setting button to call up the target temperature value. Press the increase or decrease button to change the parameter. The parameter confirmation save method is the same as before. The same applies hereinafter and will be omitted.
★ If you do not press any button for 5 seconds, the setting state will be automatically exited, and the parameter will not be memorized.
2 Ao1 menu is the ignition start temperature value option; default value: 130 ° C; setting range: 100-190 ° C.
Meaning: After reaching this temperature value, it is allowed to start work.
3 SC menu is the error correction value option; default value: 0; setting range: ±20 °C.
Meaning: When the current temperature is found to be different from the value measured by the standard thermometer, this value can be set according to the error value to correct the current temperature value to reduce the error.
4 HHH menu is the high temperature protection value option; default value: 450; setting range: 300-500 ° C, NCP.
Meaning: The system automatically protects after reaching this temperature, and the system forcibly stops the electromagnetic pump output.
NCP has no over-temperature protection. After exceeding 500 °C, HHH is not stopped.
5 ddH menu is the delay ignition time option; default value: 0; setting range: 0-20 seconds.
Meaning: After the electromagnetic pump is working, the ignition output will start after the corresponding time delay.
6 odH menu is the continuous ignition time option; default value: 6; setting range: 1-20 seconds.
Meaning: After the electromagnetic pump is working, the ignition output will stop after the corresponding time.
7 The oPP menu is the boot gear option; the default value is 2; the setting range is 0-5.
Meaning: The value of the fire position when starting up.
8 SPP menu is the shutdown gear option; default value: 1; setting range: 0-1.
Meaning: 1 is automatically returned to the second gear after shutdown, and then boot is the second gear. 0 is to keep the original gear after the shutdown, and then the original gear is activated.
9 SoP menu is the rocker switch start and stop mode option; default value: 1; setting range: 0-1.
Meaning: When the parameter is 0, the system can only start and stop by pressing the start/stop button; when the parameter is 1, the system can increase the function of starting and stopping by pressing the increase/decrease button, the rocker switch or the rotary firepower adjustment knob.
10 FHS menu is soft and hard start option; default value: 1; setting range: 0-1.
Meaning: 0 is a hard start, that is, booting directly from the start gear. 1 is a slow start, that is, it automatically rises from the 2nd gear slowly when it is turned on, until it increases to the gear position before the shutdown. Slow start is only valid when the SPP parameter option is 1.
11 SEP menu is the power knob speed option; default value: 3; setting range: 1-30.
Meaning: The adjustment amount corresponding to the minimum angle of the firepower adjustment knob can also be understood as the speed adjusted during rotation. The smaller the value, the finer the adjustment, the slower it is, and vice versa.
12 2SP menu is water cooling start temperature option; default value: 210 degrees; setting range: target temperature +1 degree – 250 degrees.
The meaning of the parameter is: when the temperature is higher than this temperature, the water cooling is started, and the control temperature is kept below 210.
13 The oPE menu is the inlet valve time factor option; default value: 5; setting range: 0-50.
The meaning of the parameter is: the time coefficient of the inlet valve opening, that is, the continuous water intake. The larger the coefficient, the larger the water intake, and the faster the cooling, and the slower.
14 The CLo menu is the inlet valve closing time option; default value: 10S; setting range: 0-60.
The meaning of the parameter is: control the closing time of the inlet valve, that is, the time to stop the water inlet. The larger the value, the less the water intake, the slower the cooling, and the faster the reverse. work process:
Power on to the OFF state, press the Start / Stop button to enter the preheating state, the heating lamp lights up, the digital tube displays the current temperature and gear position, the output of the heating tube has an output of 220V to start heating, when the temperature reaches 130 °C, the status light Start flashing, the prompt can start combustion, the status light turns to steady after the start, the ignition and the oil pump start to have output and the corresponding indicator lights up. After 6 seconds, the ignition stops, the indicator light goes out, and the combustion state is entered. At this time, there is still output at the output end of the heating tube, and the heating lamp is still lit until the current temperature reaches the target temperature, the heating is stopped and the heating lamp is extinguished.
After the current temperature reaches the target temperature, if the operation is not started by pressing the “Start/Stop” button, the system enters the thermal insulation working state, and the heating and heating is automatically performed. The temperature of the burner is always maintained near the target temperature, ready to start working.
Firepower adjustment method: 1 Press the “increase or decrease” button during the combustion process, and the firepower will gradually increase and decrease the gear position according to the set value of the gear position. 2 Rotating the power knob during the combustion process, the firepower can be continuously and smoothly adjusted.
Stop method: 1 Press the “Start/Stop” button during combustion. 2 Press “Firepower Knob” during combustion. 3 Rotate the “Firepower Knob” counterclockwise to the minimum firepower during combustion and rotate. 4A file status and then press the minus button. 5 first gear state and then operate the rocker switch downshift.
Power-on method: Press the “Start/Stop” button when the 1 status light is flashing. 2 Press the “Firepower Knob” when the status light is flashing. 3 When the status light is flashing, turn the “Firepower Knob” clockwise. 4 Press the Add button while the status light is flashing. 5 When the status light is flashing, operate the rocker switch to increase the gear.
After using the above 12 shutdown and then booting, it is started from the system default gear.
After using the above 345 to shut down and then boot, it is started from the first gear.
Shutdown method: Press and hold the “Start/Stop” button or “Firepower Knob” for about 3 seconds during the stop or combustion work, and the system will enter the OFF state.
After the temperature of the burner reaches the water-cooling starting temperature during operation, the water-cooled solenoid valve automatically starts and stops until the temperature reaches the starting temperature of -5 °C. Fault code level processing:
★ Display LLL: 1 When the power is turned on, the LLL may be low. In this case, as long as the heating lamp is bright, it will be normal after the furnace is warmed up. 2 During the heating process, the temperature value does not rise and fall, and finally “LLL” is displayed: the polarity of the thermocouple is reversed, and the transfer can be normal. 3 LLL appears on the cooker that has been used for a period of time. First remove the line of the rocker switch do not touch the wire!. If it returns to normal, it means that the rocker switch is caused by water, and it can be replaced.
★ Display HHH: 1 When the power is turned on, HHH is displayed. It may be that the thermocouple related line is not connected or disconnected. After the fault is removed, press the Burn Start/Stop button to return to normal. 2 HHH occurs during the combustion process. This is an over-temperature alarm, that is, the temperature exceeds the maximum value allowed by the system. After stopping the cooling, press the combustion start-stop button to return to normal.
★ Display E-3: Heating failure. 1 If the burner is not hot, the heating tube will be blown or the heating wire will fall off. 2 The heat of the burner is the failure of the thermocouple.
★ There is a deflagration sound when igniting: the pump parameter of the starting gear can be reduced or the ignition can be set to delay 2-3 seconds to start the ignition.
Brand BESFUL Model LC-215B + Type of intelligent temperature control regulator Measuring range -20 ~ + 140 Measurement error -10 ~ + 10 the opening size 51x71 mm Installation type window mounted output signal 6000 mA Operating voltage 220 V Dimensions 55x75x85 mm Code Senation Job Description Setting range default value 1-H temperature difference 0-80 ℃ 10 ℃ 1-P temperature difference lower limit hysteresis 1-30 ℃ 5 ℃ PH collector plate antifreeze temperature control value -1-8 ℃ 3 ℃ HS ℃ high temperature zone temperature deviation correction value -10-10 ℃ 0 ℃ LS ℃ low temperature zone deviation correction [...]
88.00 $ Add to cartHW-103 igniter: also known as industrial furnace pulse ignition controller, this product is mainly used for ignition and control of various industrial equipment and hotel stoves using liquefied gas, natural gas, artificial gas. Power-on ignition or switch-controlled ignition accidental flameout key ignition function, ion flame automatic monitoring function and flameout alarm, ignition failure and accidental flameout automatically cut off gas source safety protection, using microcomputer digital control technology, using lightning protection technology Power-on ignition/switch Control the ignition, stop the ignition after the flame is automatically detected, the solenoid valve keeps the combustion indicator light on, and when the ignition time [...]
92.50 $ Add to cartBasic parameters 1, rated working voltage: AC220V 2, normal working voltage range: AC187-242V 3, the service life: the number of actions is not less than 100,000 times 4, fan power: no more than 600W 5, ignition output: AC220V, power is not more than 100W 6, electromagnetic pump / valve output: AC220V, power is not more than 100W 7, circulating water pump output: AC220V, power is not more than 1000W Wiring instructions 1. Brown-blue black sheathed wire: Connected to 220V AC power supply, the leakage circuit breaker and a bipolar switch should be installed at the front end of the power [...]
140.00 $ Add to cartY2 commercial gas stove flameout safety protection ignition controller function description This controller is used on commercial stoves, can realize automatic high-energy ignition, accidental flameout protection, and meet the automatic control and safety protection of modern kitchen stoves. 1. Basic parameters of Y2 commercial stove flameout safety protection controller 1. Product model: Y2. 2. Operating voltage range: AC175-245V 3. Service life: ≥100,000 times 4. Ignition intensity: high-energy ignition, which can easily ignite combustible gas and various alcohol-based biofuels. 5. There is a safety protection function for accidental flameout. When the flameout is accidentally closed, the solenoid valve will be turned [...]
146.25 $ Add to cartF2 type with fine adjustment anti-air burning commercial stove controller description The controller is suitable for the alcohol oil electromagnetic pump injection combustion system with blower, has infrared automatic air defense burning function, external igniter, can realize automatic high energy ignition and air defense burning, can meet the automatic control and safety energy saving needs of modern kitchen stoves. . Basic parameters 1, rated working voltage: AC220V 2, normal working voltage range: AC187-242V 3, the service life: the number of actions is not less than 100,000 times 4, fan power: no more than 300W 5, igniter power: AC220V, no more [...]
208.75 $ Add to cartGN-787E quick-loading alcohol base material electric heating vaporization controller function description The controller is a moisture-proof structure of the whole plastic shell, and has its own lead-out line, which is used for electric heating and alcohol-free gasification stove without fan, in addition to the functions of conventional heating, temperature measurement, temperature control, ignition output, electromagnetic pump gear output and the like. There is also a model with its own precision fire regulation to choose, which can realize the stepless precision adjustment and start and stop control of the oil pump flow. This function and the gear position adjustment realize the [...]
402.50 $ Add to cartAlcohol base material without fan electrification controller function description The controller is a moisture-proof structure of the whole plastic shell, and has its own lead-out line, which is used for electric heating and alcohol-free gasification stove without fan, in addition to conventional heating, temperature measurement, temperature control, inside igniter ignition high-voltage output, electromagnetic pump In addition to the functions such as built-in, there is also a model with its own precision fire regulation, which can realize stepless precision adjustment and start/stop control of the oil pump flow. This function and gear position adjustment realizes no need to switch, fire with [...]
415.00 $ Add to cartAlcohol based electric heating vaporization controller function description The controller is a moisture-proof structure of the whole plastic shell, and has its own lead-out line, which is used for electric heating and alcohol-free gasification stove without fan, in addition to conventional heating, temperature measurement, temperature control, inside igniter ignition high-voltage output, electromagnetic pump In addition to the functions such as built-in, there is also a model with its own precision fire regulation, which can realize stepless precision adjustment and start/stop control of the oil pump flow. This function and gear position adjustment realizes no need to switch, fire with heart, [...]
527.50 $ Add to cartDescription: Features: 1 out 1 and 1 out 2 can be freely used, can be used. This product is a piezoelectric igniter, the external material is PP plastic, mainly used in gas stoves / ovens, with an ignition needle to play an ignition role. Specifications: Item Type: Piezo Spark Ignition Set Material:Plastic Cable Length: 1 m/3.3feet Output Terminals: 2.3 mm/0.09inch Installation Hole: 18 mm/0.71inch Output Voltage: ≥18KV3PF Type: 1 Out [...]
Portable Electric Arc Lighter USB Rechargeable Windproof Electronic Lighter Eco-friendly Aromatherapy for Candles Gas Stoves Feature: 1.Windproof and Flameless Technology: The Arc lighter adopt windproof design and flameless plasma technology to protect the electric pulse from being blown out by strong wind or wet weather. 2.Safty Protection: Its so much easier to light candles with this than traditional butane lighters or matches. A safety lock design keeps children away from fire. The long and flexible soft head allows you to keep a safe distance from sparks. 3.USB Charging: The lighter uses a lithium [...]
N series atomization controller description This series of controllers is used in conjunction with a methanol spray burner for ignition and fire regulation. With the extinguishing function, it can be used in places such as steaming furnaces. System parameter setting method: Press and hold the setting button to enter the system parameter setting, turn the knob to select the desired menu, press the setting button to display the value, turn the knob to adjust the value, and then press and hold the setting button until the SAU is displayed, indicating that the saving is successful. Note: If you do not [...]
177.50 $ Add to cartAlcohol base material without fan electrification controller function description The controller is a moisture-proof structure of the whole plastic shell, and has its own lead-out line, which is used for electric heating and alcohol-free gasification stove without fan, in addition to conventional heating, temperature measurement, temperature control, inside igniter ignition high-voltage output, electromagnetic pump In addition to the functions such as built-in, there is also a model with its own precision fire regulation, which can realize stepless precision adjustment and start/stop control of the oil pump flow. This function and gear position adjustment realizes no need to switch, fire with [...]
415.00 $ Add to cartbody, td, th { font-family: Verdana, Geneva, sans-serif; font-size: 18px; color: #636363; } body { margin-left: 0px; margin-top: 0px; margin-right: 0px; margin-bottom: 0px; } a { color: #636363; text-decoration: none; } a:hover { text-decoration: none; color: #636363; } a:active { text-decoration: none; color: #636363; } em { color: #BD1A1D; font-style: normal; font-weight: 700; } Electric Arc Lighter USB Rechargeable Flameless Windproof Flexible Candle Lighters for BBQ Stovetop SCVD889 Features: Type:Electric Arc Lighter Material:Aluminum Alloy Fire mode:Arc Description: 1.Rechargeable Battery:Arc lighters are powered by rechargeable Lithium-Ion 220mAh batteries that can be recharged [...]
Function description of alcohol-based fuel vaporization controller for precise regulation of firepower The controller is used for electric heating and alcohol-free gasification stove without fan, in addition to the functions of conventional heating, temperature measurement, temperature control, ignition, electromagnetic pump speed regulation, etc., it can also expand external precision regulator to achieve precise adjustment of oil pump flow and Start-stop control, this function and gear position adjustment achieve the effect of no need to switch, fire with heart, start and stop freely. At the same time, it can also extend the external word reset rocker switch or the third gear [...]
415.00 $ Add to cartFunction description of alcohol-based fuel vaporization controller for precise regulation of firepower The controller is used for electric heating and alcohol-free gasification stove without fan, in addition to the functions of conventional heating, temperature measurement, temperature control, ignition, electromagnetic pump speed regulation, etc., it can also expand external precision regulator to achieve precise adjustment of oil pump flow and Start-stop control, this function and gear position adjustment achieve the effect of no need to switch, fire with heart, start and stop freely. At the same time, it can also extend the external word reset rocker switch or the third gear [...]
477.50 $ Add to cartChcę coś kupić ale szukam informacji jak zamówić... |
Kupiłem coś ale chcę poznać status zamówienia... |
Odebrałem paczkę ale mam pytanie lub problem... |
Chcę dokonać zwrotu i potrzebuję informacji... |
Droptech Sp. z o.o. droptech.polska@gmail.com |
ul. Łódzka 118, Piotrków Tryb. Sprzedajemy tylko przez internet |
NIP: 7712911090 REGON 386758083 |
Wysyłka bezpośrednio od producenta lub dostawcy |
DARMOWA WYSYŁKA + ubezpiecznie dostawy + śledzenie przesyłki |
CAŁKOWITY ZWROT podczas reklamacji |
Reviews
There are no reviews yet.